Description

10,600nm CO2 · 7 Scan Shapes · Fractional & Ultra-Pulse Modes

Resurface Skin, Refine Scars & Target Pigmentation

The 7 scan shape CO2 fractional laser brings adjustable fractional resurfacing, four ultra-pulse cutting waveforms and dedicated intimate-care handpieces into one wheeled workstation. Pattern size and density controls, touchscreen operation and articulated-arm delivery help trained providers adapt coverage for scars, uneven texture, visible pigmentation and other permitted professional applications.

10,600nm CO2Sealed CO2 platform with articulated-arm energy delivery.
7 Scan ShapesAdjustable size and density for varied treatment areas.
Four Head TypesFractional, ultra pulse and two intimate-care heads shown.
Workstation ControlTouchscreen, key switch, foot control and water connections.

Explore the Treatment Platform

One Workstation, Three Distinct Treatment Categories

This system is differentiated by its clearly separated operating categories. The fractional head supports patterned skin resurfacing, the ultra-pulse head provides four displayed cutting waveforms, and the dedicated intimate-care heads extend the platform into professional vaginal treatment workflows where permitted.

That modular setup can help established clinics consolidate several compatible CO2 services around one treatment-room workstation while maintaining separate consultation, protocol and safety pathways for each mode.

How the 10,600nm Fractional Mode Works

The image documentation identifies a 10.6μm CO2 wavelength delivered through an articulated arm. In fractional mode, the beam is divided into separated microbeams that create microscopic treatment zones while leaving intervening areas untreated.

This pattern supports controlled resurfacing and the tissue-remodeling response associated with collagen renewal. Buyers comparing tissue interaction and delivery principles can review how a fractional CO2 laser system is used within professional resurfacing platforms.

Visible aiming guidance: the product material shows a red aiming beam used to indicate where the invisible infrared treatment beam is directed.
Seven Scan Shapes with Adjustable Size & Density

The fractional scanner displays seven geometric choices so operators can adapt coverage to different treatment zones. The supplied images also state that scan size and density are adjustable.

Point
Linear
Rectangle
Triangle
Hexagon
Square
Round

Pattern, size, density and energy choices should follow professional assessment, operator training, the supplied manual and the intended treatment endpoint.

Fractional Resurfacing Applications
Skin ResurfacingSupports professional renewal plans for rough and uneven texture.
Scar RemodelingTargets the appearance of suitable acne, surgical and trauma scars.
Stretch MarksExtends resurfacing consultations to selected body texture concerns.
Fine LinesAdds a controlled option for visible aging and crow’s-feet concerns.
Visible PigmentationMay support selected pigmentation protocols after assessment.
Skin LaxitySupports collagen-focused services for firmer-looking skin.
Ultra-Pulse Head with Four Cutting Waveforms

The ultra-pulse head screen shows four waveform options for professional cutting-mode workflows. The product images associate this mode with selected epidermal lesions, including moles and flat warts.

Cutting applications must be restricted to appropriately qualified and legally authorized medical professionals. Diagnosis, lesion selection, pathology considerations, local rules and the exact device registration must be confirmed before use.

Dedicated Intimate-Care Handpieces

The documented configuration shows separate handpieces labeled for vaginal tightening and vaginal whitening, including a longer 360-degree delivery probe. The marketing materials also reference dryness, tissue softness and postpartum care.

These are professional intimate-care applications—not consumer self-treatment claims. Availability, permitted indications, patient selection, contraindications, operator qualifications and consent requirements vary by jurisdiction. The fixed percentage claims shown in the source images are not repeated here because supporting clinical evidence was not provided.

Workstation Components & Treatment-Room Control
Confirmed Component Role in the Workflow
Touchscreen Central interface for selecting and adjusting available operating modes.
Articulated Laser Arm Transfers CO2 energy toward the selected treatment head.
Key Switch Supports controlled access to system operation.
Foot Switch Provides operator-controlled activation within supported modes.
Water Inlet / Outlet Part of the system’s documented water-circulation connections.
Wheeled Chassis Supports positioning within an appropriately prepared treatment room.
Professional Buyers & Business Fit

This model is suited to established buyers seeking more than a single-mode resurfacing device. Its fractional, cutting and intimate-care hardware creates distinct service possibilities, provided each application falls within the buyer’s professional qualifications and local regulatory scope.

CE-Certified Professional PlatformThe system is CE-certified. Buyers may request the applicable CE documentation and model-specific compliance information for purchasing records and destination-market review.
  • Aesthetic and dermatology clinics
  • Medical spas with legally authorized operators
  • Plastic-surgery and skin-health practices
  • Women’s health or intimate-care practices where permitted
  • Distributors sourcing multi-mode CO2 workstations
Configuration & Documentation to Confirm

The images confirm the visible platform and operating categories but do not provide a complete specification sheet. Before ordering, request written confirmation of:

  • Exact model number, laser source, rated output and pulse parameters
  • Scan-size and density ranges for all seven patterns
  • Included heads, lenses, aiming-beam specification and accessories
  • Cooling requirements, voltage, dimensions, net weight and packing list
  • Operator manual, installation, training and after-sales arrangements
  • Written warranty terms and the CE documents applicable to the ordered model

Teams comparing installation and ongoing service requirements should request current laser technical support details for the exact configuration and destination market.

Safety & Professional-Use Notice
CO2 laser equipment can ablate tissue and may cause burns, scarring, pigment changes, infection, plume hazards or eye injury when used improperly. Fractional, cutting and intimate-care modes require application-specific training, suitable eye protection, controlled access, plume management, assessment, consent and aftercare. The machine must be operated only by appropriately qualified and legally authorized professionals.
Frequently Asked Questions

What differentiates this system from the earlier CO2 products?

This model is documented as a black-and-gray wheeled workstation with seven adjustable scan shapes, fractional and ultra-pulse modes, four cutting waveforms and two dedicated intimate-care heads.

What wavelength does it use?

The supplied working-theory image identifies the CO2 wavelength as 10.6μm, equivalent to 10,600nm.

Are all four treatment heads included?

The images show fractional, ultra-pulse, vaginal-whitening and vaginal-tightening heads. Confirm the final packing list and exact configuration in writing before purchase.

Are the before-and-after results or percentage claims guaranteed?

No. Marketing images illustrate intended applications, but results vary. Fixed improvement percentages are not repeated without applicable clinical evidence.

Is this system CE-certified?

Yes. CE documentation applicable to the ordered model can be requested for purchasing and destination-market review. Warranty coverage should be confirmed in the written quotation.

Configure Your Multi-Mode CO2 Workstation

Bring Fractional, Ultra-Pulse & Specialty CO2 Modes into One Treatment Room

Contact MECAVIE for complete technical specifications, scan ranges, included heads, installation requirements, training options, product documentation and current pricing.

Request Full Specs & Pricing

Reviews

There are no reviews yet.

Be the first to review “7 Scan Shape CO2 Fractional Laser – Resurface Skin, Refine Scars & Target Pigmentation”

Your email address will not be published. Required fields are marked *