1927nm and 1550nm Dual-Wavelength Laser – Target Pigmentation, Texture & Fine Lines

$9,986.00

🚢
Free Shipping
3-5 days · Tracking

🛡️
After-Sales Support
2-year service · Tech support

✅
CE Certified
Professional grade

Get instant quote & assistance

196 in stock

Description

1927nm + 1550nm · 30W output · Dual-wavelength fractional delivery

Two Wavelengths for Pigmentation, Texture & Skin Renewal

The 1927nm and 1550nm dual-wavelength laser combines two fractional fiber wavelengths, adjustable scan graphics, fractional and super-pulse operating modes, and multiple treatment tips in one professional tabletop system. The configuration supports pigmentation-focused care, skin-texture refinement, pore appearance, acne-scar protocols and visible fine-line treatments.


1927nm + 1550nm


Two fractional fiber wavelengths within one professional platform.

1–30W Output


Adjustable power range stated in the supplied technical sheet.

6 Scan Graphics


Oval, triangle, custom, square, round and hexagon.

Multiple Treatment Tips


Fractional, sliding, precision, focused and rotation options.

Explore the Dual-Wavelength Platform

One Platform with Two Fractional Wavelengths

The system integrates 1927nm and 1550nm fiber-laser bands into one tabletop workstation. Operators can select the appropriate wavelength, treatment tip, scan graphic and operating parameters according to the treatment area and planned professional protocol.


1927nm Wavelength


Positioned for superficial pigmentation, uneven-looking tone, dull skin and surface-focused renewal protocols.

1550nm Wavelength


Positioned for skin texture, enlarged-pore appearance, acne-scar care and visible fine-line protocols.

The two wavelengths provide complementary treatment-planning options without requiring separate single-wavelength workstations.

How Dual-Wavelength Fractional Delivery Works

Fractional delivery creates controlled treatment zones while leaving surrounding areas untreated. The system allows the operator to configure wavelength, pulse width, pulse energy, dot spacing, scan graphic and treatment area according to the selected protocol.

The 1927nm option is positioned for more superficial pigmentation and tone concerns, while the 1550nm option supports protocols focused on texture, enlarged-pore appearance, acne scars and fine lines.

Buyers comparing treatment coverage and parameter control can review
fractional scanning technology
alongside the operating manual for the exact configuration.

Wavelength selection, treatment settings and patient suitability must be determined by trained professionals according to the operating manual and applicable local requirements.

Fractional Tips & Sliding Treatment Tips

The supplied materials show separate fractional and sliding treatment tips for the two wavelengths. A 9 × 9mm fractional tip is also displayed.


1927nm Fractional Tip


Controlled fractional delivery using the 1927nm wavelength.

1550nm Fractional Tip


Fractional protocols using the system’s second wavelength.

9 × 9mm Tip


A defined treatment window for repeatable fractional coverage.

Sliding Tips


Separate sliding accessories are displayed for 1927nm and 1550nm.

The included tip combination may vary by order. Confirm all required fractional and sliding tips in the final quotation and packing list.

Precision, Focused & 360° Rotation Probes

In addition to the fractional and sliding tips, the supplied product materials identify three application-specific probe styles.


Precision Probe


Designed for precise positioning and targeted professional operation.

Focused Probe


Designed for localized application within compatible protocols.

360° Rotation Probe


Designed to support circumferential energy delivery.

Application-specific probes require suitable training, individual assessment and confirmation that the intended procedure is permitted for the ordered model and destination market.

Professional Skin-Treatment Applications

The product materials present the platform for professional treatment planning involving visible pigmentation, uneven tone, rough texture and signs of photoaging.


Dark Spots & Pigmentation


Protocols focused on visible pigmentation and sun-related spots.

Uneven-Looking Tone


Treatment planning for dull or uneven-looking coloration.

Acne-Scar Appearance


Texture-focused fractional treatment protocols.

Enlarged Pores


Protocols designed around visible pore and texture concerns.

Fine Lines


Selected visible-aging and photoaging consultations.

Rough Skin Texture


Professional texture-refinement and renewal workflows.

Before-and-after images illustrate promoted applications and do not guarantee individual results. Outcomes depend on patient selection, treatment parameters, technique, treatment course and aftercare.

Six Scan Graphics & Adjustable Coverage

The supplied technical sheet identifies six treatment graphics and two scan modes. Adjustable dot spacing and graphic size help adapt the treatment pattern to different areas.

Oval
Triangle
Custom
Square
Round
Hexagon
  • Order and freedom scan modes
  • 0.1–2.0mm adjustable dot pitch
  • 0.1 × 0.1mm–20 × 20mm graphic-size range
  • 0.1–10ms pulse-width range
  • 1–300mJ adjustable pulse energy

Confirmed Technical Parameters
Laser type Fiber
Wavelength bands 1927nm + 1550nm
Operating modes Fractional pulse, super pulse
Power 1–30W
Scan graphics Oval, triangle, custom, square, round, hexagon
Scan modes Order, freedom
Pulse width 0.1–10ms
Dot pitch 0.1–2.0mm adjustable
Focused spot size ≥0.1mm
Graphic size 0.1 × 0.1mm–20 × 20mm
Pulse energy 1–300mJ adjustable
Cooling system Air cooling
System languages Chinese and English
Input voltage 110–240V AC

Parameters are taken from the supplied technical image. Confirm the final specification sheet and electrical configuration before ordering.

OEM, ODM & Distribution Support

The supplied materials present factory-direct supply, OEM/ODM customization and order-fulfillment support for clinics, distributors, online sellers and developing beauty-equipment brands.

Buyers requiring private-label projects can discuss branding, interface options, packaging and accessory combinations through the available
laser clinic equipment
supply program.


OEM / ODM


Branding and configuration consultation.

Quality Inspection


Pre-shipment equipment inspection.

Order Fulfillment


Factory-direct shipping coordination.

Worldwide Delivery


International logistics consultation.

OEM, ODM, local-warehouse and dropshipping availability depends on the destination, order quantity and agreed commercial terms.

Specifications & Documentation to Request

Product images confirm the principal feature categories but do not replace a complete quotation, specification sheet or packing list. Before ordering, request written confirmation of:

  • Exact model number and output specification
  • 1927nm and 1550nm wavelength configuration
  • Fractional and super-pulse operating controls
  • All six scan graphics and two scan modes
  • Included fractional and sliding treatment tips
  • Included precision, focused and 360° probes
  • Graphic-size, pulse-width and energy ranges
  • Electrical and installation requirements
  • English-language operating manual
  • Application-specific training information
  • Certification documents for the exact model
  • Written warranty and after-sales terms

Frequently Asked Questions

What distinguishes this model from the 1927nm-only product?

This model combines 1927nm and 1550nm wavelengths, giving professional users separate options for pigmentation-focused and texture-focused protocols.

Can the two wavelengths be selected separately?

The product materials show separate 1927nm and 1550nm fractional and sliding tips. Confirm wavelength-selection controls and supplied accessories for the ordered configuration.

Are all pictured probes included?

The images display fractional, sliding, precision, focused and 360° rotation options. The final included set must be confirmed in the quotation and packing list.

Are treatment results guaranteed?

No. The supplied before-and-after images illustrate promoted applications. Individual results depend on assessment, settings, technique, treatment course and aftercare.

Is CE documentation available?

CE documentation is available for this product line. Request documents matching the exact model, configuration and destination market before ordering.

Professional-use notice:

Fractional laser equipment can cause burns, pigment changes, scarring, infection or eye injury when used improperly. Treatments require qualified operators, patient assessment, suitable eye protection, controlled access, informed consent and application-specific safety protocols.

Add Two Fractional Wavelengths to One Treatment Platform

Request the complete configuration, accessory list, technical documentation and pricing.


Request Specs & Pricing

Reviews

There are no reviews yet.

Be the first to review “1927nm and 1550nm Dual-Wavelength Laser – Target Pigmentation, Texture & Fine Lines”

Your email address will not be published. Required fields are marked *